HVAC PROFESSIONAL FORMULATOR includes all 200 formulas of the HVAC Fomulator and adds 18 charts, as well as the complete International Mechanical Code. A future upgrade (free for current users) will add the International Energy Code. Here is a list of many of the formulas:Air Change Ratio Equations Air Change Rate Per Hour Air Change Rat Per Hour Metric Air Flow Rate AIRSIDESensible Heat Latent Heat Airside Total Heat Airside Metric Sensible Heat Metric Latent Heat (Lbs)BOILER Generational Efficiency Generational Efficiency With Thermal BTU CONVERSIONSDuctwork Velocity Velocity Pressure Total Pressure Round Ductwork Equivalent Round ENERGY (BOTH BTU and JOULES)Crude OilMotor Gasoline Aviation Gasoline Jet Fuel Lpg Propane Ethanol ButaneKerosene Residual Oil Anthracite Coal Bituminous Coal Natural Gas HEATING DESIGN Electric Heating Unit Electric Baseboard Heat Tracing Cable Hydronic Snow Melting Gas-Fired Radiant Ceiling Electric Heating Design Load Hot Water Heating System Design Boiler Design Capacity Boiler Area Baseboard Heating Load Steam Heating System Heating Capacity HEATING REQUIREMENT Average Insulation Good Insulation HUMIDITYSpecific Humidity Relative Humidity Sensible Heat Humidity Latent Heat Sensible LOADS Temperature Load Heat from Lights Heat from Electric Equipment Heat from Machines Open Expansion Tank Required Volume Pressure in a Mixture Effective Pressure PIPINGArea of Pipe Wall Weight of Pipe Cast-Iron Pipe Steel Pipe Copper Pipe Steel Pipe Equations Cross Sectional Area Outside Surface Area Per Foot Inside Surface Area Total Area of Metal Expansion in Plastic Piping Expansion in Inch Hazen William Friction Head Loss Friction Head Loss Equivalent Length Piping Elbows Piping Gate Valves Pie Length Change Due to Temperature Pipe Chase Size Change Due to length Chase Width Chase DepthTotal Fall45 Degree Offset PUMP LAWS Break Horsepower Ft of Water Pump Suction Head REFRIGERATION Chiller Unit Tonnage Output Air Unit Tonnage Output Chiller Coefficient Compression Ratio Mass Flow Rate STEAM Pounds Per Steam Per Hour Condensate Loads Lbs of Steam Water Fuel Oil Gas/AirTEMPERATURE Mixed Air Mixing Two Liquids- Temperature Final Temperature Mix WATERSIDE SYSTEM Total Heat Waterside Evaporator Water Flow Rate Condenser Water Flow Rate Waterside Metric Total Heat Metric

HVAC Professional alternatives

Psyclone HVAC Lite

Psyclone Lite by Silverglance Software provides a toolkit of HVAC psychrometric calculations for low-volume flowrate systems (up to 2000 cfm / 1 m3/s), allowing individual processes to be examined and supply air volume, condition or capacity to calculated. Psyclone Lite can be upgraded to remove flowrate restrictionsPsyclone operates in either metric or imperial units.

  • size 1.4 MB

HVAC Psychrometric Plus

The HVAC Psychrometric Plus app is the #1 selling psychrometric application for the Apple iPhone and iPad. Thousands of happy users have downloaded this useful application for performing quick and simple psychrometric analysis. HVAC Psych HD

  • size 19.1 MB

iManifold

The iManifold App Calculates HVAC/R system performance and troubleshoots system problems through user inputs and dynamic, live system data. With over 40 selectable refrigerants and equipment profiling options, the iManifold app can be custom tailored for many common HVAC/R systems in the field.

  • size 29.2 MB

Ductulator - Duct Sizer

A compact Metric and Imperial Duct Sizer aka Ductulator. Combines the ease of a visual wheel for rough sizing and a numeral calculator for more precise calculations. Developed by Engineers for Everyone.

  • rating 3.375
  • size 6.2 MB

Thermostats

Free to download to see whats available inside app. If upgraded to paid version this app gives you access to over 400+ name brand thermostat manuals to be easily downloaded and shared. Download for free with very limited access then if it looks like you could use this app upgrade to paid version for full access.

  • rating 4.5
  • size 10.0 MB