HVAC FORMULATOR is the perfect tool for any Heating Ventilating and Air Conditioning Professional. This program contains nearly 200 formulas helpful HVAC Professionals. HVAC FORMULATOR formulas include:Air Change Ratio Equations Air Change Rate Per Hour Air Change Rat Per Hour Metric Air Flow Rate AIRSIDESensible Heat Latent Heat Airside Total Heat Airside Metric Sensible Heat Metric Latent Heat (Lbs)BOILERGenerational Efficiency Generational Efficiency With Thermal BTU CONVERSIONSBtu to CaloriesBtu to Cubic foot-AtmBtu to Foot pounds Btu to Foot-LbfBtu to Gram-Cal Btu to Gram-CmsBtu to Horsepower-HrBtu to Inch-LbfBtu to JoulesBtu to KilocaloriesBtu to Liter-AtmBtu to Pounds-CalBtu to Watt-HrDUCTWORK Velocity Velocity Pressure Total Pressure Round Ductwork Equivalent Round ENERGYCrude OilMotor Gasoline Aviation Gasoline Jet Fuel Lpg Propane Ethanol ButaneKerosene Residual Oil Anthracite Coal Bituminous Coal Natural Gas HEATING DESIGNElectric Heating Unit Electric Baseboard Heat Tracing Cable Hydronic Snow Melting Gas-Fired Radiant Ceiling Electric Heating Design Load Hot Water Heating System Design Boiler Design Capacity Boiler Area Baseboard Heating Load Steam Heating System Heating Capacity HEATING REQUIREMENTS Average Insulation Good Insulation HUMIDITYSpecific Humidity Relative Humidity Sensible Heat Humidity Latent Heat Sensible LOADSTemperature Load Heat from Lights Heat from Electric Equipment Heat from Machines Open Expansion Tank Required Volume Pressure in a Mixture Effective Pressure PIPING Area of Pipe Wall Weight of Pipe Cast-Iron Pipe Steel Pipe Copper Pipe Steel Pipe Equations Cross Sectional Area Outside Surface Area Per Foot Inside Surface Area Total Area of Metal Expansion in Plastic Piping Expansion in Inch Hazen William Friction Head Loss Friction Head Loss Equivalent Length Piping Elbows Piping Gate Valves Pie Length Change Due to Temperature Pipe Chase Size Change Due to length Chase Width Chase Depth PUMP LAWSBreak Horsepower Ft of Water Pump Suction Head REFRIGERATIONChiller Unit Tonnage Output Air Unit Tonnage Output Chiller Coefficient Compression Ratio Mass Flow Rate STEAMPounds Per Steam Per Hour Condensate Loads Lbs of Steam Water Fuel Oil Gas/AirTEMPERATUREMixed Air Mixing Two Liquids- Temperature Final Temperature Mix WATERSIDE SYSTEMTotal Heat Waterside Evaporator Water Flow Rate Condenser Water Flow Rate Waterside Metric Total Heat Metric

HVAC Formulator alternatives

testo Smart Probes

The testo Smart Probes APP makes your mobile device to a remote control and measurement data centre. Application specific menus (e.g.):- AC + Refrigeration: automatic calculation of system parameters, like superheat or subcooling- Volume Flow (outlet / duct): easy set up of your measurement and performing a punctual or continuous measurement.- IR Temperature and Mould Indication: contactless temperature measurement with fast photo documentation and detection of areas with mould risk. 15m (depends on mobile device used)Preconditions for using:- Use a testo Smart Probe (testo 405i, 410i, 605i, 510i, 115i, 549i, 805i, 905i), a testo 552 or a testo 770-3- Requires iOS 8.3 or newer, plus mobiles end device with Bluetooth 4.0

  • size 62.9 MB

Psyclone HVAC Lite

Psyclone Lite by Silverglance Software provides a toolkit of HVAC psychrometric calculations for low-volume flowrate systems (up to 2000 cfm / 1 m3/s), allowing individual processes to be examined and supply air volume, condition or capacity to calculated. Psyclone Lite can be upgraded to remove flowrate restrictionsPsyclone operates in either metric or imperial units.

  • size 1.4 MB

iManifold

The iManifold App Calculates HVAC/R system performance and troubleshoots system problems through user inputs and dynamic, live system data. With over 40 selectable refrigerants and equipment profiling options, the iManifold app can be custom tailored for many common HVAC/R systems in the field.

  • size 29.2 MB

Munters PsychroApp

Munters PsychroApp is the quick and easy psychrometric calculation tool designed for the iPhone and iPod touch which can run unmodified on an iPad too making accurate calculations of the thermodynamic properties of moist air easy. Calculate the total, sensible, latent and moisture loads of any process more accurately than using psychrometric charts. Air and Water Vapour Properties in PsychroAppPsychrometricFdb / Cdb - Dry Bulb TemperatureFwb / Cwb - Wet Bulb Temperature%RH - Relative HumidityBtu/lb / kJ/kg - EnthalpyFdp / Cdp - Dew Point Temperaturegr/lb / g/kg - Humidity Ratioft/lb - m/kg - Specific Volumein Hg VP / mm Hg VP - Vapour Pressurelb/ft / kg/m - DensityPPMw - Parts Per Million by weightPPMv - Parts Per Million by volumegr/ft / g/m - Absolute HumidityPressureAlt in Ft / m - Altitude (elevation)psia / kPa - Absolute PressurePsychroApp is registered software from Munters - the leading energy efficient air treatment company

  • size 3.1 MB

ManTooth

The YELLOW JACKET ManTooth app receives live HVAC/R pressure, temperature, and vacuum readings from one or more ManTooth V, PT, or PTV Modules (hardware purchase required) through wireless Bluetooth connections. The pressure, temperature, and vacuum readings are displayed, along with key system analysis data, in an easy-to-read format with screenshot and data log sharing capability. SHARINGShare your screenshots and data logs with others by email, adding other information or attachments as needed.

  • rating 4.2
  • size 20.4 MB